Titan UV Sterilisers
Photocatalytic-enhanced UV sterilisation engineered for the demands of commercial aquatic operations. Not a bigger version of a consumer unit — a fundamentally different technology.


~33%
More effective than standard UV
40 yrs
of UV expertise
24/7
Pathogen control
Beyond UV. Photocatalytic Enhancement.
Standard UV sterilisers rely on direct photonic exposure. The Titan adds a photocatalytic reactor stage that generates hydroxyl radicals — one of the most powerful oxidising agents available in water treatment — extending the sterilisation effect.
Photocatalytic Reactor
UV light activates the catalyst coating, producing hydroxyl radicals that oxidise organic and inorganic compounds in the water stream. Net result: cleaner water chemistry, not just reduced pathogen count.
Individually Chambered Lamps
Each lamp occupies its own chamber, minimising UV penetration depth to the critical zone. Pathogens receive the full dose — not a diluted pass through a shared column.
Fused Quartz Glass Sleeves
Fused quartz transmits UVc more effectively and maintains optimal lamp temperature — ensuring maximum UVc output throughout the lamp's rated life.
Built for Commercial Environments
Every component choice on the Titan reflects a commercial operating context — high run-hours, pressurised systems, minimal downtime tolerance, and the need for rapid maintenance by non-specialist staff.
IP67 Control Gear Connectors
Tool-free maintenance
Rated to IP67 and designed for simple disconnect and reconnect without tools. Reduces service time and eliminates the risk of incorrect reassembly in wet commercial environments.
Translucent Lamp Caps
Visual status check
Lamp operational status is visible without disassembly. In a commercial system running multiple units, this is a significant time-saver during routine inspection rounds.
8,000hr Lamp Life
55W UV lamp
Rated at 8,000 hours — approximately 11 months of continuous operation* before replacement. Predictable, schedulable maintenance intervals rather than reactive failures.
(*TMC recommends lamp changes every 6 months in critical applications)
<2 psi Pressure Drop
Pressurised system compatible
Low hydraulic resistance means the Titan can be integrated inline into pressurised recirculation systems without requiring a dedicated low-head pump or bypass arrangement.
Available in both Floor standing and Wall mount versions.
Flexible installation
Mounting hardware supports both floor-standing and wall-mounted installations. Accommodates the constrained plant-room layouts typical in commercial aquaria and aquaculture facilities.
110–240V / 50–60Hz
International compatible
Wide input voltage range supports deployment across UK, EU, and international markets without voltage conversion. Relevant for export customers and multinational operations.
Engineered for These Environments
The Titan is not a consumer product scaled up. It is specified and sold to operations where UV sterilisation is a critical process control — not an optional extra.
01
Public Aquaria & Zoo Exhibits
High visitor footfall, diverse livestock, and zero tolerance for disease outbreaks. The Titan provides the sterilisation consistency required for mixed-species display systems running 365 days a year.
02
RAS Fish Farming
Recirculating aquaculture systems demand tightly controlled water quality at high flow rates. Photocatalytic enhancement reduces organic load and pathogen pressure across the recirculation loop.
03
Shellfish Depuration & Holding
Shellfish depuration requires treated, pathogen-reduced seawater held to food safety standards. The Titan's hydroxyl radical chemistry addresses both biological and chemical contamination simultaneously.
04
Commercial Ornamental Wholesalers
Ornamental importers and wholesalers move high densities of livestock through quarantine and holding systems. Reliable sterilisation at the holding stage protects the entire stock and reduces medication costs.
Specifications & Spares
| Parameter | Value / Detail |
|---|---|
| Brand | Biosystems |
| UV Lamp Power | 55W |
| Lamp Life | 8,000 hours rated |
| Lamp Sleeves | Fused quartz glass |
| Lamp Configuration | Individually chambered |
| Enhancement Technology | Photocatalytic reactor |
| Connector Rating | IP67 |
| Pressure Drop | <2 psi |
| Pipe Size | 2 inches |
| Input Voltage | 110–120V / 220–240V |
| Frequency | 50Hz & 60Hz |
| Mounting | Floor & wall mount options |
| Warranty | 24 months |
Genuine Spare Parts
Use only genuine Biosystems replacement lamps and control gear to maintain performance specifications and warranty validity. Scheduled lamp replacement at 8,000 hours is recommended regardless of visible lamp condition.
24-Month Commercial Warranty
Backed by Tropical Marine Centre with a 2-year warranty when installed and used within our guidelines.
Titan vs Vecton: Choosing the Right UV
Both ranges use quality UVc technology. The choice comes down to application scale, the value of photocatalytic enhancement, and the maintenance requirements of your operation.
| Criterion | Titan UV (PL-TCOMUV) | Vecton Range |
|---|---|---|
| Primary market | Commercial / trade operations | Hobbyist / advanced aquarist |
| Photocatalytic enhancement | ✓ Hydroxyl radical generation | ✗ UV-only |
| Sterilisation effectiveness | Up to ~33% above standard UV | Standard UVc baseline |
| Lamp configuration | Individually chambered | Open chamber |
| Glass sleeves | Fused quartz | Standard glass / quartz dependent on model |
| IP-rated connectors | ✓ IP67 | ✗ Standard |
| Visual lamp status | ✓ Translucent caps | ✗ Disassembly required |
| Warranty | Backed by Tropical Marine Centre with a 2-year warranty when installed and used within our guidelines |
Standard TMC warranty |
| Pressurised system compatible | ✓ <2psi pressure drop | Model dependent |
Not Sure What You Need? Start with the UV Calculator.
TMC's UV Calculator walks you through the key variables for UV steriliser sizing — tank volume, water type, stocking density, and target UV dose. It's the fastest way to establish a baseline specification before talking to our commercial team.
1
Volume, water type, and stocking load. Commercial systems should factor total recirculating volume, not just display tank capacity.
2
Clarification, disease control, or full Level 3 sterilisation. Commercial and public aquaria operations typically require Level 3.
3
The calculator outputs a unit recommendation. If your system falls into commercial territory, that's where the Titan UV comes in — bring the output to our team for a full specification discussion.
Ready to Specify the Titan UV?
Talk to the Biosystems technical team about flow rates, system integration, and volume pricing. We support specifiers, systems integrators, and direct commercial operators.